What Extension Cord Do Outdoor Decorations Need?

The lights at the far end of the run are noticeably dimmer than the ones near the house, and the cord is warm in the middle. Is that normal?

the short answer

No, and both symptoms are the same problem: the cord is too thin for the length of the run. Use a cord marked for outdoor use — look for W or SJTW on the jacket — and size it by distance rather than by what fits the budget. Sixteen gauge is fine under 50 ft, 14 gauge from 50 to 100 ft, and 12 gauge beyond that. A thin cord on a long run drops voltage, which dims the far end and turns the lost energy into heat in the cable.

6 minute read.

The two things on the jacket that matter

Everything you need is printed on the cord itself, in small raised letters along the jacket. Two parts of it decide whether the cord is right.

The first is a W, usually as part of a code like SJTW or SJEOW. The W means the jacket is rated for wet and cold conditions. A cord without one is an indoor cord, and an indoor cord outdoors in December goes stiff, then cracks at the bends, and the cracks are where water gets to copper.

The second is the gauge, written as a number and the letters AWG. This is where people go wrong, because the scale runs backwards: 12 gauge is thicker than 14, which is thicker than 16. Lower number, heavier cord, more current it can carry over a longer distance without losing voltage.

A third marking is worth a glance: the amp or watt rating, usually on the tag. If a cord does not state one at all, that is itself informative.

What gauge for what distance

Sized for the loads a yard display actually puts on a cord, which is a few amps run continuously for six or seven hours rather than a brief heavy draw.

Run length Gauge Carries comfortably What happens if you go thinner
Under 25 ft16 AWGUp to about 13 ampsVery little. This is the one case where the cheap cord is genuinely fine.
25 to 50 ft16 AWGUp to about 10 ampsNoticeable dimming only if you are near the top of the load.
50 to 100 ft14 AWGUp to about 12 ampsA visibly dimmer far end, and a cord that is warm to the hand along its length.
100 to 150 ft12 AWGUp to about 13 ampsReal voltage drop. Inflatable blowers labour and can fail to inflate fully.
Over 150 ft12 AWG, or move the outletDiminishing returnsAt this distance the cord costs more than an electrician charges to put a receptacle where you actually need one.

A cord warm enough to notice is a cord converting your electricity into heat instead of delivering it. It is both the waste and the warning.

Why the far end goes dim

Every foot of cable has a small resistance, and pushing current through resistance costs voltage. The longer and thinner the cable, the more of the 120 volts is spent getting there rather than arriving.

LEDs mostly shrug this off, which is why an all-LED display can survive a bad cord and only look slightly wrong. Incandescent mini lights show it immediately and go orange. Inflatable blowers are the ones that genuinely suffer: a motor fed low voltage draws more current to do the same work, gets hot, and either underinflates the piece or shortens its own life.

The practical rule is to keep any one run as short as the yard allows, and to run two shorter cords from two outlets rather than one long one daisy-chained across the lawn. Two 50 ft runs are electrically much better than one 100 ft run, even though they cost about the same.

Connections, which is where the failures actually happen

Cords rarely fail along their length. They fail where two of them meet, because that is where water gets in, and a joint lying on wet grass is a joint sitting in a puddle by Tuesday.

Give every connection a drip loop: let the cord dip below the joint before it rises into it, so water running down the cable falls off the bottom of the loop instead of tracking into the plug. It costs nothing and two seconds, and it is the single highest-value habit in this entire article.

Keep joints off the ground where you can — clipped to a fence rail, a stake, anything a few inches up. Where they must be near the ground, a connection cover, which is a plastic clamshell costing a few dollars, does the job properly. Taping a joint with electrical tape does not: tape traps the water that does get in and holds it against the metal.

And do not run a cord under a rug, a doormat or a path of stepping stones. Every year somebody does it to hide the cable and produces a cord that is being slowly crushed with nobody able to see the damage.

do this arithmetic once

Add up the amps of everything that will be on the far end of one cord. Inflatables are roughly 1.0 to 1.5 amps each and their blowers never stop; LED strings are about 0.2 amps per set and barely register.

If the total is over about 10 amps you are into 14 gauge regardless of distance, and over 12 amps you have exceeded what a single 15 amp household circuit should carry all evening and the cord is no longer the problem. That is a second circuit, not a thicker cable.

Where this usually goes wrong

Buying by length and price, and ignoring the gauge

A 100 ft 16 gauge cord and a 100 ft 12 gauge cord sit next to each other on the shelf and one is half the price. They are not the same product. At that distance the cheap one will dim the far end of the display and warm up doing it.

Daisy-chaining three cords to reach the corner

Each joint is a place for water to get in and each length adds voltage drop. One correctly sized cord beats three short ones end to end, and two runs from two outlets beat both.

Using an indoor cord because it is only for a few weeks

A few weeks is the whole season, in the wet and the cold, which is exactly the condition an indoor jacket is not rated for. It goes stiff and cracks at the bends, and the cracks are not visible until you go looking.

Leaving the reel coiled

A cord run at anything near its rating while still wound on its reel cannot shed heat, because every turn is warming the turn beside it. Unwind the whole thing even when you only need half of it.

plot it in your own yard

Every plan on this site totals the outlets and the amps before anything is bought, so you can size the cord for the load rather than discovering it in the dark.

Pick your lot shape

Read next

Do Outdoor Holiday Lights Need a GFCI Outlet?

Yes, and it is not a formality. A GFCI cuts power in about a fortieth of a second when current starts going somewhere it should not, which outdoors in December it eventually will.

Read it

How Many Inflatables Can You Run on One Circuit?

Four, and that is before the lights. The blower runs all night, which changes the arithmetic from the one people do in their head.

Read it

How Many Christmas Lights Do I Actually Need?

One division, and the number you divide by is not the number on the box. Get it wrong and the run ends three feet short of the corner.

Read it

more like this

New guides go up through the season

Each one is a lot shape or a problem worked all the way through, the same as this one, and they are all free to read. No schedule worth promising, but they keep coming.

One email when there is something new. Nothing else, ever.